Assessing the efficacy of electrocardiogram for heart rate evaluation during newborn resuscitation at birth: a prospective observational study
Clin Exp Emerg Med. 2025;12(2):164-168.   Published online October 16, 2024
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Assessing the efficacy of electrocardiogram for heart rate evaluation during newborn resuscitation at birth: a prospective observational study
Clin Exp Emerg Med. 2025;12(2):164-168.   Published online October 16, 2024
Close
Objective
This study assessed the efficacy of electrocardiogram (ECG) compared to pulse oximetry (PO) in detecting heart rate (HR) during high-risk newborn resuscitation. Methods A prospective observational study was performed with high-risk delivery cases to measure the time required for HR detection. A conventional PO and a standard ECG monitor were used for HR assessment. Results Forty-one infants were analyzed in the study, and 11 needed resuscitation. The study population was divided according to gestational age (GA): 9 were GA <32 weeks, 28 were GA 32–35 weeks, and 4 were GA ≥36 weeks. Time from ECG placement to HR detection (median, 30 seconds; interquartile range [IQR], 20–43.5 seconds) was significantly faster than that from PO placement (median, 125 seconds; IQR, 100–175 seconds; P<0.001). Time from ECG placement to HR detection was shortest in infants with GA <32 weeks at birth (19 seconds [IQR, 11.5–30.0] for GA <32 weeks vs. 34.5 seconds [IQR, 25.0–44.3] for GA 32–35 weeks vs. 39.5 seconds [IQR, 30.0–64.8] for GA ≥36 weeks; P=0.039). Conclusion ECG effectively evaluated HR during neonatal resuscitation compared to PO. Low- GA infants who require resuscitation may benefit from HR evaluation with nearby standard ECG.

Citations

Citations to this article as recorded by  Crossref logo
  • Wireless monitoring directly after birth in term neonates: A feasibility study
    Marisse Meeus, Heleen Dingemanse, Corrie Jacobs, Maartje van Dalen, Anne Nieuwenhuis, Julie Lateur, Irma Pernot
    Early Human Development.2026; 213: 106454.     CrossRef
  • Non-Contact and Wireless Wearable Technologies for Neonatal Vital Sign Monitoring in the Delivery Room—A Scoping Review
    Eva Sutera, Alyssa Maximov, Vívian Mara Gonçalves de Oliveira Azevedo, Wissam Shalish, Robert Kearney, Guilherme M. Sant’Anna
    Children.2026; 13(8): 1025.     CrossRef
  • 4,649 View
  • 62 Download
  • 2 Web of Science
  • 2 Crossref