Skip to main navigation Skip to main content

CEEM : Clinical and Experimental Emergency Medicine

OPEN ACCESS
ABOUT
BROWSE ARTICLES
FOR CONTRIBUTORS

Page Path

2
results for

"Gastrointestinal hemorrhage"

Article category

Publication year

Keywords

"Gastrointestinal hemorrhage"

Original Articles

Gastrointestinal

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Association of inferior vena cava diameter ratio with outcomes in patients with gastrointestinal bleeding
Clin Exp Emerg Med. 2022;9(2):101-107.   Published online June 10, 2022
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Association of inferior vena cava diameter ratio with outcomes in patients with gastrointestinal bleeding
Clin Exp Emerg Med. 2022;9(2):101-107.   Published online June 10, 2022
Close
Objective
To examine the association of inferior vena cava (IVC) diameter ratio measured using computed tomography with outcomes in patients with gastrointestinal bleeding (GIB).
Methods
A single-center retrospective observational study was conducted on consecutive patients with GIB who presented to the emergency department. The IVC diameter ratio was calculated by dividing the maximum transverse and anteroposterior diameters perpendicular to it. The association of the IVC diameter ratio with outcomes was examined using multivariable logistic regression analysis. The primary outcome was in-hospital mortality. The area under the receiver operator characteristic curve (AUC) of the IVC diameter ratio was calculated, and the sensitivity and specificity, including the cutoff values, were computed.
Results
In total, 585 patients were included in the final analysis. The in-hospital mortality rate was 4.6% (n=27). The IVC diameter ratio was significantly associated with higher in-hospital mortality in multivariable logistic regression analysis (odds ratio, 1.793; 95% confidence interval [CI], 1.239–2.597; P=0.002). The AUC of the IVC diameter ratio for in-hospital mortality was 0.616 (95% CI, 0.498–0.735). With a cutoff of the IVC diameter ratio (≥2.1), the sensitivity and specificity for predicting in-hospital mortality were 44% (95% CI, 26%–65%) and 71% (95% CI, 67%–75%), respectively.
Conclusion
The IVC diameter ratio was independently associated with in-hospital mortality in patients with GIB. However, the AUC of the IVC diameter ratio for in-hospital mortality was low.

Citations

Citations to this article as recorded by  Crossref logo
  • Can point-of-care ultrasound improve the predictive accuracy of early warning scores in critically ill emergency department patients?: A prospective observational study
    Süreyya Tuba Fettahoğlu, Serkan Doğan, Salih Fettahoğlu, Melih Uçan, Bilal Yeniyurt, Vildan Avcu, Efe Demir Bala, Utku Murat Kalafat
    Medicine.2026; 105(7): e47663.     CrossRef
  • Association of inferior vena cava diameter, functional disability, and dehydration with clinical outcomes in elderly patients
    İbrahim Halil Toksul, İbrahim Altundağ
    Irish Journal of Medical Science (1971 -).2026; 195(5): 3195.     CrossRef
  • 8,036 View
  • 228 Download
  • 2 Web of Science
  • 2 Crossref

Imaging | Gastrointestinal

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Diagnostic accuracy and implementation of computed tomography angiography for gastrointestinal hemorrhage according to clinical severity
Clin Exp Emerg Med. 2016;3(2):69-74.   Published online June 30, 2016
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Diagnostic accuracy and implementation of computed tomography angiography for gastrointestinal hemorrhage according to clinical severity
Clin Exp Emerg Med. 2016;3(2):69-74.   Published online June 30, 2016
Close
Objective
This study compared the diagnostic accuracy of computed tomography (CT) angiography in patients with various severities of gastrointestinal hemorrhage (GIH).
Methods
We retrospectively enrolled adult patients (n=262) with GIH who had undergone CT angiography from January 2012 to December 2013. Age, sex, comorbidities, presenting symptoms, initial vital signs, laboratory results, transfusion volume, emergency department disposition, and hospital mortality were abstracted from patient records. CT angiography findings were reviewed and compared to reference standards consisting of endoscopy, conventional angiography, bleeding scan, capsule endoscopy, and surgery, either alone or in combination. Clinical severity was stratified according to the number of packed red blood cell units transfused during the first two days: the first quartile was categorized as mild severity, while the second and third quartiles were categorized as moderate severity. The fourth quartile was categorized as severe.
Results
Patients were categorized into the mild (n=75, 28.6%), moderate (n=139, 53.1%), and severe (n=48, 18.3%) groups. The mean number of transfused packed red blood cell units was 0, 3, and 9.6 in the mild, moderate, and severe groups, respectively. The overall sensitivity, specificity, positive predictive value, and negative predictive value of CT angiography were 73.8%, 94.0%, 97.3%, and 55.3%, respectively. The area under the receiver operating characteristics curve for the diagnostic performance of CT angiography was 0.780, 0.841, and 0.930 in the mild, moderate, and severe groups, respectively, which significantly differed among groups (P=0.006).
Conclusion
The diagnostic accuracy of CT angiography is better in patients with more severe GIH.

Citations

Citations to this article as recorded by  Crossref logo
  • The Accuracy of Computed Tomography Angiography Compared With Technetium-99m Labelled Red Blood Cell Scintigraphy for the Diagnosis and Localization of Acute Gastrointestinal Bleeding: A Systematic Review and Meta-Analysis
    Kaspar L. Yaxley, Ali Mulhem, Sean Godfrey, Jason L. Oke
    Current Problems in Diagnostic Radiology.2023; 52(6): 546.     CrossRef
  • Delayed endoscopy is associated with increased mortality in upper gastrointestinal hemorrhage
    Namkyung Jeong, Kyung Su Kim, Yoon Sun Jung, Taegyun Kim, So Mi Shin
    The American Journal of Emergency Medicine.2019; 37(2): 277.     CrossRef
  • Comparison of the National Early Warning Score+Lactate score with the pre-endoscopic Rockall, Glasgow-Blatchford, and AIMS65 scores in patients with upper gastrointestinal bleeding
    Daejin Kim, Sion Jo, Jae Baek Lee, Youngho Jin, Taeoh Jeong, Jaechol Yoon, Boyoung Park
    Clinical and Experimental Emergency Medicine.2018; 5(4): 219.     CrossRef
  • 18,585 View
  • 106 Download
  • 4 Web of Science
  • 3 Crossref