Abstract
-
Objective
This study aimed to assess the diagnostic value of the sagittal and transverse views of the suprapubic window during a Focused Assessment with Sonography in Trauma (FAST) or extended FAST (eFAST) examination.
-
Methods
This retrospective chart review analyzed suprapubic windows of FAST/eFAST images performed from August 15, 2017, to August 1, 2024. Each ultrasound video was reviewed for the presence or absence of free fluid, image quality, and diagnostic confidence. Reviewers were blinded to clinical information and did not assess more than one imaging plane in the same patient.
-
Results
Of the 958 FAST/eFAST studies identified, 497 met inclusion criteria. Of these, 433 (87.1%) were diagnostic, while 64 (12.9%) were nondiagnostic in at least one imaging plane. Among diagnostic images, 93 (21.5%) sagittal views and 74 (17.1%) transverse views were positive for free fluid. A total of 32 exams (34.4%) showed free fluid in the sagittal views but were negative on the transverse view, whereas 13 cases (17.6%) were positive on the transverse view but negative on the sagittal view. Using both views reduced overall nondiagnostic rate from 12.9% to 1.2%.
-
Conclusion
Using both sagittal and transverse views in the suprapubic window during a FAST/eFAST examination can reduce the nondiagnostic rates and improve identification of free fluid. The observed discrepancies between views and variability in the image quality and confidence support a multiview approach.
-
Keywords: Focused Assessment with Sonography in Trauma (FAST); Trauma; Point-of-care ultrasound; Ultrasound; Imaging planes
Capsule Summary
What is already known
The Focused Assessment with Sonography in Trauma (FAST) examination is commonly performed for trauma. The suprapubic view can be visualized in the sagittal plane, transverse plane, or both planes.
What is new in the current study
Among 433 FAST examinations where the suprapubic view was visualized in both planes, 12.9% were nondiagnostic in at least one imaging plane. Among diagnostic images, 21.5% of sagittal views and 17.1% of transverse views were positive for free fluid; 34.4% showed free fluid in the sagittal views but were negative on the transverse view, whereas 17.6% were positive on the transverse view but negative on the sagittal view.
INTRODUCTION
Point-of-care ultrasound (POCUS) has been increasingly utilized by clinicians in the emergency department to conduct rapid bedside assessments of undifferentiated patients, allowing initiation of early care while minimizing radiation exposure [
1,
2]. The Focused Assessment with Sonography in Trauma (FAST) examination and its extended version (extended FAST, eFAST) are among the most common POCUS examinations performed [
3]. The FAST/eFAST examination are critical elements in the evaluation of free fluid in the context of trauma, concern for ruptured ectopic pregnancy, or guiding paracentesis in patients with ascites. The eFAST examination has been shown to be 98% specific, but only 74% sensitive for detecting intra-abdominal free fluid in trauma patients [
4].
The abdominal component of the FAST/eFAST examination includes perihepatic, perisplenic, and suprapubic windows. Each window offers the ability to evaluate different recesses prone to occult fluid collection. While the perihepatic and perisplenic windows are traditionally imaged in the sagittal plane, the approach to the suprapubic window has been more variable, with some experts recommending a single plane while others suggest imaging in both sagittal and transverse planes [
5]. Despite robust literature on the FAST/eFAST examination, there have been limited studies directly comparing the transverse and sagittal views of the suprapubic windows to inform clinical practice and standardization of research protocols.
To address this gap, our study aimed to determine the interrater reliability of the sagittal versus transverse views of the suprapubic window during a FAST/eFAST examination. Secondary outcomes included nondiagnostic rates, image quality, and physician confidence with each imaging plane.
METHODS
Ethics statement
This study was approved by the Institutional Review Board of Rush University (No. 23022002-IRB01). The requirement for informed consent was waived due to the retrospective nature of the study. This study adhered to the STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) guidelines and best practices in chart review methodology [
6,
7].
Study design and setting
This was a retrospective study comparing the sagittal versus transverse views of the suprapubic window of a FAST/eFAST examination. This was conducted in the Department of Emergency Medicine, Rush University Medical Center, a quaternary care academic institution with an annual volume of 74,000 patients per year. The institution has a 3-year emergency medicine residency program and a 1-year clinical ultrasound fellowship.
All FAST/eFAST images performed, regardless of indication, from August 15, 2017 (first available image) to August 1, 2024, were eligible for inclusion. Exclusion criteria consisted of absence of a suprapubic view, only a single imaging plane available, wrong examination performed (e.g., examination labeled as FAST, but images were of the aorta), duplicate studies (defined as two studies performed on the same patient within the same hour), and studies with no interpretable suprapubic view images.
An ultrasound fellowship-trained physician screened all FAST/eFAST studies in the database (QpathE, Telexy Healthcare) by first sorting by categorical labeling (FAST or eFAST), followed by manual review of each video loop within each examination to determine eligibility. All video clips were set to 6 seconds. A subset (10% of cases) was dual-reviewed by a second ultrasound fellowship-trained physician for accuracy. To ensure blinding, neither of these physicians were involved in the video analysis stage. The physicians then numerically coded each image and split them into sagittal versus transverse for each patient. All images were obtained by one of the following machines: Zonare Z1Pro, Zonare ZS-3, Mindray TE 7, or Mindray TE X (all from Mindray Medical).
Four ultrasound fellowship-trained experts with >1,000 prior quality-assurance reviews independently reviewed the ultrasound images from the included cases (
Fig. 1). Each reviewer was blinded to the clinical information (including the ultrasound report) and did not assess more than one imaging plane in the same patient (i.e., a different reviewer assessed the sagittal versus the transverse in a given patient). Reviewers were assigned to evaluate only a single imaging plane but were not randomized at the image level. Data were reported on a prepiloted, standardized data collection form. The data collection form included the following variables: study ID, image view (sagittal vs. transverse), free fluid diagnosis (absent, present, indeterminate), quality of image (scale, 1–5) based upon the imaging criteria defined by the American College of Emergency Physicians [
8], and reviewer confidence in making the free fluid diagnosis based on the images (scale, 1–5) [
9]. Categorization of a view as diagnostic (i.e., free fluid present or absent) versus nondiagnostic (i.e., indeterminate) was based on the expert physician’s determination of the ability to adequately assess the presence or absence of fluid based upon the corresponding video.
Statistical analysis
Data were presented descriptively as counts and percentages or mean±standard deviation. Kappa with 95% confidence intervals (CIs) was calculated for interrater reliability and paired sample t-test was used for differences in quality and confidence scores between the sagittal and transverse clips. All analyses were performed with IBM SPSS ver. 26.0 (IBM Corp).
RESULTS
A total of 958 stored FAST/eFAST studies were available from August 15, 2017, to August 1, 2024. Of these, 497 (51.9%) met inclusion criteria and were included in this review. The majority of images were excluded due to obtaining only a single suprapubic imaging plane or no suprapubic images (
Fig. 2).
Of the 497 studies that were reviewed, 433 (87.1%) included diagnostic quality views in both imaging planes, while 58 (11.7%) had diagnostic quality views in only a single imaging plane and 6 (1.2%) had no diagnostic quality images in either plane. Of the 433 studies with diagnostic quality images in both planes, 93 (21.5%) were positive for free fluid in the sagittal plane and 74 (17.1%) were positive for free fluid in the transverse plane (
Table 1). Of the 93 studies with positive free fluid on sagittal views, 32 (34.4%) had no evidence of free fluid in the transverse view. Conversely, of the 74 studies with positive free fluid on the transverse views, 13 (17.6%) had no evidence of free fluid in the sagittal view. When comparing sagittal and transverse images, we found a κ coefficient of 0.667 (95% CI, 0.577–0.757), which demonstrated moderate agreement for the presence or absence of fluid.
Of the 64 nondiagnostic studies, 34 (53.1%) were nondiagnostic on the sagittal alone, while 24 (37.5%) were nondiagnostic on the transverse alone. There were six studies (9.4%) that were nondiagnostic on both the sagittal and transverse views (
Table 2).
When evaluating image quality, the sagittal plane had a mean quality rating score of 3.45±0.95 and the transverse plane had a mean quality rating score of 3.29±0.78. When comparing quality scores, the sagittal plane had a slightly higher quality rating (0.16; 95% CI, 0.07–0.24).
When evaluating confidence to make a diagnosis based on the video clip, the sagittal plane had a mean confidence score of 3.60±1.02 and the transverse plane had a mean confidence score of 3.73±1.03. When comparing confidence scores, the sagittal plane had a slightly lower confidence rating (–0.13; 95% CI, –0.24 to –0.02).
DISCUSSION
The FAST examination is a core element of emergency medicine practice; however, there are currently variations in the protocol for the suprapubic imaging approaches. In this retrospective review comparing the transverse and sagittal imaging planes in 497 FAST/eFAST studies, we found that when both sagittal and transverse suprapubic imaging planes were adequately obtained, each plane independently contributed to the detection of free fluid. Notably, 21.5% of sagittal views and 17.1% of transverse views were positive for free fluid, with moderate interrater agreement between planes (κ=0.667), highlighting that discordant findings between planes are not uncommon. These findings support the routine acquisition of both sagittal and transverse suprapubic views during FAST examinations, as relying on a single plane may lead to missed identification of intra-abdominal fluid. Incorporating dual-plane imaging into training curricula and documentation protocols may improve diagnostic reliability and reduce missed detections of free fluid.
Approximately one-third of the studies reviewed were excluded due to the inclusion of only a single suprapubic imaging plane. This highlights the real-world variation in performance and a potential opportunity to enhance diagnostic accuracy. In our study, we found that using both imaging planes reduced the overall nondiagnostic rate from 12.9% to 1.2%, equating to a number-needed-to-diagnose (i.e., the number of FAST/eFAST examinations performed with two views needed to enhance the diagnostic image rate) for free fluid of 9 [
10].
In addition, over one-third of sagittal-positive exams had no corresponding free fluid on transverse, and nearly one-fifth of transverse-positive exams lacked free fluid on sagittal imaging. This adds further evidence suggesting that omitting either view can compromise diagnostic sensitivity. This is consistent with other research, which has demonstrated that fluid, particularly in trauma, is not evenly distributed among body fields [
11]; this further emphasizes the necessity of utilizing multiple imaging planes to avoid a misdiagnosis. Future work should prospectively explore the impact of the two-plane pelvic imaging on enhancing the sensitivity of the FAST/eFAST examination.
Image quality was slightly higher in the sagittal plane, while provider confidence was marginally higher in the transverse plane. These subtle differences may reflect differences in the ease of probe positioning, anatomical familiarity, or imaging clarity between the two planes. However, the differences between values were small and both views achieved reasonably high scores, supporting their overall utility and reliability.
We identified moderate agreement for the presence or absence of free fluid between imaging planes. This aligns with prior research on the FAST examination comparing different abdominal views, which has also reported moderate interrater agreement across different anatomic locations [
12]. Considering the difference in diagnostic quality image and discordant findings of free fluid between the sagittal and transverse suprapubic views, we believe these should be considered complementary rather than redundant, much the same as adding multiple anatomic locations (i.e., right upper quadrant, left upper quadrant, and suprapubic) has been considered.
Limitations
This study has several limitations. First, it was conducted at a single academic center which may limit the generalizability of the results. Second, the sonographers reviewing the images are all ultrasound fellowship-trained emergency physicians which could differ from less advanced users. Third, there was no definitive gold standard (e.g., operative findings, computed tomography) used to verify the presence or absence of free fluid in the suprapubic area. As a result, the determination of diagnostic accuracy was based on image interpretation and interrater agreement which may not fully capture clinical outcomes. Additionally, not all patients included in the study were confirmed to be acute trauma patients. Some ultrasound examinations may have included studies with patients who had ascites or other intra-abdominal fluid, which differs in clinical context. Finally, we evaluated image quality and confidence comparing the sagittal and transverse view during the suprapubic window assessment in isolation. We did not assess other relevant factors such as time required to obtain views or body habitus, which can influence reliability when scanning. These limitations highlight the need for prospective, multicenter studies to further define the diagnostic benefit of two ultrasound imaging planes in the assessment of intraabdominal fluid.
Conclusions
This study reinforces the importance of incorporating multiple imaging planes for the suprapubic portion of the FAST/eFAST examination. By combining sagittal and transverse views, clinicians can increase the number of examinations with at least one diagnostic quality image and may enhance the ability to diagnose free fluid.
NOTES
-
Author contributions
Conceptualization: all authors; Investigation: all authors; Project administration: all authors; Supervision: MG; Visualization: all authors; Writing–original draft: all authors; Writing–review & editing: all authors. All authors read and approved the final manuscript.
-
Conflicts of interest
Michael Gottlieb is an associate editor of this journal, but was not involved in the peer reviewer selection, evaluation, or decision process of this article. The authors have no other conflicts of interest to declare.
-
Funding
The authors received no financial support for this study.
-
Data availability
The data analyzed in this study are available from the corresponding author upon reasonable request and with completion of a data use agreement.
Fig. 1.Suprapubic ultrasound views. (A) Transverse view with free fluid present (arrows). (B) Sagittal view with free fluid present (arrow).
Fig. 2.Study flow diagram. FAST, Focused Assessment with Sonography in Trauma; eFAST, extended Focused Assessment with Sonography in Trauma.
Table 1.Cross-tabulation of FF detection between sagittal and transverse views during FAST/eFAST examination
Table 1.
|
Transverse view |
|
Sagittal view |
FF absent |
FF present |
Total |
|
FF absent |
327 |
13 |
340 |
|
FF present |
32 |
61 |
93 |
|
Total |
359 |
74 |
433 |
Table 2.Comparison of diagnostic versus nondiagnostic suprapubic images by sagittal versus transverse imaging plane during a FAST/eFAST examination
Table 2.
|
Transverse view |
|
Sagittal view |
Diagnostic |
Nondiagnostic |
Total |
|
Diagnostic |
433 |
24 |
457 |
|
Nondiagnostic |
34 |
6 |
40 |
|
Total |
467 |
30 |
497 |
REFERENCES
- 1. Miller DL, Abo A, Abramowicz JS, et al. Diagnostic ultrasound safety review for point-of-care ultrasound practitioners. J Ultrasound Med 2020;39:1069-84.
- 2. Barton MF, Barton KM, Goldsmith AJ, et al. POCUS-first in acute diverticulitis: quantifying cost savings, length-of-stay reduction, and radiation risk mitigation in the ED. Am J Emerg Med 2025;88:204-12.
- 3. Gottlieb M, Cooney R, King A, et al. Trends in point-of-care ultrasound use among emergency medicine residency programs over a 10-year period. AEM Educ Train 2023;7:e10853.
- 4. Netherton S, Milenkovic V, Taylor M, Davis PJ. Diagnostic accuracy of eFAST in the trauma patient: a systematic review and meta-analysis. CJEM 2019;21:727-38.
- 5. Von Kuenssberg Jehle D, Stiller G, Wagner D. Sensitivity in detecting free intraperitoneal fluid with the pelvic views of the FAST exam. Am J Emerg Med 2003;21:476-8.
- 6. von Elm E, Altman DG, Egger M, et al. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. J Clin Epidemiol 2008;61:344-9.
- 7. Kaji AH, Schriger D, Green S. Looking through the retrospectoscope: reducing bias in emergency medicine chart review studies. Ann Emerg Med 2014;64:292-8.
- 8. American College of Emergency Physicians (ACEP). Emergency ultrasound standard reporting guidelines. ACEP; 2018.
- 9. Gottlieb M, Patel D, Sundaram T. Comparison of endotracheal tube location on ultrasound accuracy, time, and confidence. Am J Emerg Med 2022;62:127-8.
- 10. Amini R, Patanwala AE, Shokoohi H, Adhikari S. Number needed to scan: evidence-based point-of-care ultrasound (POCUS). Cureus 2021;13:e17278.
- 11. Lobo V, Hunter-Behrend M, Cullnan E, et al. Caudal edge of the liver in the right upper quadrant (RUQ) view is the most sensitive area for free fluid on the FAST exam. West J Emerg Med 2017;18:270-80.
- 12. Ma OJ, Gaddis GM, Robinson L. Kappa values for focused abdominal sonography for trauma examination interrater reliability based on anatomic view and focused abdominal sonography for trauma experience level. Ann Emerg Med 2004;44(Supplement):S32-3.